More items from this sellerView All

React Health Luna G3 25A Auto-BiPAP Machine with Heated Humidifier – Quiet, Reliable Home PAP Therapy

$1,499.00 $1,899.00 Excl. tax

0 reviews

Prescription (RX)


    Upload your Prescription (RX)

    Rx  Required              Free  Shipping

    Experience advanced bilevel sleep therapy with the React Health Luna G3 25A Auto-BiPAP Machine. Designed for comfort and precision, it automatically adjusts inhalation and exhalation pressure, ensuring smooth, natural breathing. Includes a built-in heated humidifier for enhanced comfort through the night.

      Ask a Question

    Description

    React Health Luna G3 25A Auto-BiPAP Machine with Heated Humidifier – Enhanced Sleep Quality Tonight

    The React Health Luna G3 25A Auto-BiPAP Machine with Heated Humidifier is a cutting-edge home therapy device for adults managing obstructive sleep apnea. With intelligent auto pressure adjustment, a built-in heated humidifier, and quiet operation, this machine ensures comfortable, consistent, and effective nightly therapy. Ideal for home use, it provides advanced features designed to improve compliance, sleep quality, and overall health.


    Key Features of React Health Luna G3 25A Auto-BiPAP Machine with Heated Humidifier

    The React Health Luna G3 25A Auto-BiPAP Machine offers a combination of features that make it stand out:

    Auto Pressure Adjustment Technology in React Health Luna G3 25A Auto-BiPAP Machine

    The advanced sensors of the React Health Luna G3 25A Auto-BiPAP Machine with Heated Humidifier automatically detect apnea events and flow limitations, adjusting pressure in real-time to maintain open airways. This technology ensures effective therapy while minimizing discomfort for sensitive patients.

    Travel PAP Machine

    Heated Humidifier in React Health Luna G3 25A Auto-BiPAP Machine

    The React Health Luna G3 25A Auto-BiPAP Machine with Heated Humidifier comes with a built-in heated humidifier that prevents dryness in the nose and throat, making therapy more comfortable. Adjustable humidity settings allow patients to customize airflow for their personal comfort.

    Quiet and User-Friendly Design

    With noise levels below 26 dBA, the React Health Luna G3 25A Auto-BiPAP Machine operates quietly, allowing uninterrupted sleep. The intuitive color display shows therapy data, while ramp functions gradually increase pressure to help users fall asleep naturally.

    According to the Mayo Clinic, PAP therapy helps treat sleep apnea effectively


    Benefits of React Health Luna G3 25A Auto-BiPAP Machine with Heated Humidifier

    • Provides consistent and comfortable airway support

    • Reduces nasal dryness and throat irritation with humidification

    • Automatic adjustments improve compliance and therapy effectiveness

    • Compatible with most adult CPAP masks

    • Portable for travel and easy storage

    Data Tracking and Therapy Compliance

    The React Health Luna G3 25A Auto-BiPAP Machine with Heated Humidifier stores therapy data on an SD card for detailed tracking. Users and healthcare providers can monitor treatment progress, ensuring better long-term results.

    Products: Full Face Mask


    How React Health Luna G3 25A Auto-BiPAP Machine Improves Sleep Quality

    Using the React Health Luna G3 25A Auto-BiPAP Machine with Heated Humidifier can help reduce daytime fatigue, support cardiovascular health, and improve overall sleep quality. By maintaining open airways, patients experience deeper, uninterrupted sleep that restores energy and promotes well-being.

    The American Lung Association explains how sleep apnea affects breathing during sleep.

    Additional information

    Specifications

    🧾 Product Information

    Manufacturer: React Health
    In the Package: Luna G3 25A Auto-BiPAP Machine with Built-in Heated Humidifier, Humidifier Chamber, 6-Foot Standard Tubing, 2 Reusable Foam Filters (1 Pre-Installed), Universal AC Power Supply with Cord, SD Data Card, Carrying Case, User Manual

    Part Number(s): LG3625A

    HCPCS Code: E0601

    Warranty: 2 Years – Review manufacturer documentation for full details

    Intended Use: For adult patients requiring BiLevel PAP therapy prescribed for sleep apnea or related breathing disorders

    Prescription Item: Prescription required for purchase

    Country of Origin: China

    ⚙️ Physical Specifications

    Available Color(s): Black
    Size (Approx): 10.43 × 5.71 × 4.49 inches
    Weight (Approx): 3.75 lbs
    Display Type: Color LCD
    Materials: Not made with natural rubber latex

    💨 Performance Specifications

    Therapy Modes: CPAP, Auto-BiLevel (S, ST, T)
    Pressure Range: 4–25 cmH₂O
    Ramp Time: 0–60 minutes
    Sound Level: <28 dBA
    Comfort Technology: Preheat, RESlex Exhalation Relief Technology

    🔗 Compatibility

    Masks: Compatible with all CPAP & BiPAP masks
    Tubing: Compatible with all standard tubing
    Humidifiers: Integrated Heated Humidifier

    📊 Therapy Data & Compliance

    Data Storage: SD Data Card
    Data Viewing: On-screen & React Health Plus App

    💧 Humidifier Specifications

    Humidifier Type: Integrated Heated Humidifier
    Chamber Capacity: 350 mL (to maximum fill line)
    Humidifier Chambers: Standard

    ⚡ Power Specifications

    AC (Wall) Power: 100–240V AC, 50/60Hz, 2.0A
    Power Supply: Included (Universal AC Power Adapter)

    0.0 Average Rating Rated (0 Reviews)

    Rated
    0%
    Rated
    0%
    Rated
    0%
    Rated
    0%
    Rated
    0%

    Be the first to review “React Health Luna G3 25A Auto-BiPAP Machine with Heated Humidifier – Quiet, Reliable Home PAP Therapy”

    Your email address will not be published. Required fields are marked *

    You have to login to add images.

    Store
    Price
    Details
    $1,499.00 $1,899.00 Excl. tax

    Shipping Policy

    Order Processing Time

    All orders are processed within 1–2 business days.
    Orders placed on weekends or holidays will be processed on the next business day.


    2. Shipping Time

    Delivery typically takes 3–7 business days, depending on the location and courier availability.


    3. Shipping Charges

    Shipping charges are calculated at checkout based on:

    • Delivery location

    • Product weight/size

    • Selected shipping method


    4. Order Tracking

    Once your order is shipped, you will receive a tracking number via email or SMS.


    5. Delays

    We are not responsible for delays caused by:

    • Courier issues

    • Weather conditions

    • Incorrect shipping details provided by the customer


    6. Address Accuracy

    Please ensure the shipping address is correct.
    We are not responsible for:

    • Misdelivery

    • Lost packages due to incorrect addresses


    7. Damaged or Missing Items

    If your order arrives damaged or incomplete, please contact us within 48 hours with:

    • Order number

    • Photos of the package/product

    We will assist you promptly.


    8. Contact Us

    For any shipping-related questions, contact:
    📧 pmrespiratory7@cox.net
    📞 3522374545

    Refund Policy

    PM Respiratory Services – Ocala, Florida
    Last Updated: November 2025

    Thank you for choosing PM Respiratory Services. Our goal is to ensure transparency and fairness regarding refunds for our customers.


    1. Refund Eligibility

    Refunds are available only when:

    • The product is unused, unopened, and in original packaging

    • The refund request is made within 7 days of the purchase date

    • A valid receipt or proof of purchase is provided

    • The item is not a hygienic or personal-use medical product


    2. Non-Refundable Items

    For health, safety, and product integrity reasons, the following items cannot be refunded:

    • Used CPAP/BiPAP machines

    • Opened masks or accessories

    • Tubing, filters, cushions, humidifier chambers, headgear

    • Any item that is damaged, worn, or missing parts

    • Special orders or customized products

    • Clearance or discounted items


    3. Refund Process

    If approved:

    1. The product must be brought to our Ocala office

    2. Our team will inspect the item

    3. Refunds will be issued to the original payment method

      • Card: 3–5 business days

      • Cash: Same day


    4. Defective or Damaged Items

    If the product is defective or damaged at the time of purchase:

    • Report immediately or within 24 hours

    • Bring the item to the store

    • After inspection, we will provide a replacement or store credit

    Manufacturer warranties apply when available.


    5. Final Decision

    PM Respiratory Services reserves the right to approve or deny any refund based on:

    • Condition of the product

    • Safety and hygiene requirements

    • Proof of purchase


    Contact

    PM Respiratory Services
    Ocala, Florida
    Phone: 3522374545
    Email: pmrespiratory7@cox.net

    Cancellation / Return / Exchange Policy

    PM Respiratory Services – Ocala, Florida
    Last Updated: November 2025

    PM Respiratory Services (“Company”) is committed to providing high-quality medical devices and hygienic products. This policy has been created in accordance with applicable U.S. Federal and Florida State laws, FDA guidelines, and medical device safety standards.
    This policy applies to all cash customers purchasing products from the Company.


    1. Order Cancellation

    1.1 Orders may be cancelled only before packing or shipping has begun.
    1.2 Once an order is packed, shipped, or out for delivery, it becomes non-cancellable.
    1.3 The customer must submit a cancellation request immediately by phone or email with the order number.
    1.4 Approval of order cancellation is at the sole discretion of the Company.


    2. Return Policy

    Due to the nature of medical devices and hygiene regulations, returns are strictly limited.

    A return will be accepted only under the following circumstances:

    2.1 The customer received an incorrect item.
    2.2 The product was damaged at the time of delivery.
    2.3 The product is defective and non-functional upon delivery.

    Return Eligibility Requirements:

    • The customer must report the issue within 48 hours of receiving the product.

    • The item must be unused, in original condition, and in original packaging.

    • All accessories, manuals, and packaging must be included.

    • The customer must provide photo or video evidence of the issue.

    • The item must pass the Company’s inspection before approval.


    3. Non-Returnable Items

    In accordance with FDA Health & Safety Guidelines, the following items are strictly non-returnable and non-refundable under any circumstances:

    • CPAP/BiPAP masks

    • Nasal pillows and cushions

    • Tubing and filters

    • Headgear and mask accessories

    • Nebulizer kits

    • Humidifier chambers

    • Any item that contacts the face, nose, or airway

    • Opened or used medical products

    • Items with a broken hygiene seal

    • Special orders, custom orders, and clearance items


    4. Exchange Policy

    An exchange is offered only when:

    • The incorrect product was delivered, or

    • The product is defective upon delivery.

    4.1 Exchanges are subject to product availability.
    4.2 If the replacement is unavailable, the Company may issue a store credit equal to the product value.
    4.3 All exchange decisions are made solely by the Company.


    5. Refund Policy

    Refunds are processed only for Company-approved cancellations or returns.

    5.1 Refunds are issued using the same payment method used by the customer:

    • Cash refunds → same day

    • Card refunds → 5–7 business days

    5.2 Shipping, handling, and service fees are non-refundable.
    5.3 A restocking fee (up to 15%) may apply, depending on the product type and condition.
    5.4 Refunds are issued only after the returned product has been inspected and approved.


    6. Limitation of Liability

    The Company is not responsible for:

    • Damage caused by customer misuse or improper handling

    • Issues resulting from third-party installation or repair

    • Wear and tear after product acceptance

    • Any indirect, incidental, or consequential damages

    The Company’s maximum liability is limited strictly to the purchase price of the product.


    7. Final Decision

    The Company reserves the right to approve or deny any return, exchange, or refund request.
    All decisions made by the Company are final and binding.


    8. Contact Information

    PM Respiratory Services
    Ocala, Florida
    Phone: 3522374545
    Email: pmrespiratory7@cox.net

    Specifications

    • Product Type: Auto-BiPAP Machine with Heated Humidifier

    • Pressure Range: 4–25 cm H₂O

    • Humidifier: Adjustable heated water chamber

    • Noise Level: ≤26 dBA

    • Display: Color LCD with data tracking

    • Connectivity: SD card / optional cloud

    • Mask Compatibility: Standard CPAP masks

    • Intended Use: Home sleep apnea therapy for adults

    Medical Disclaimer

    This device is a medical device intended for the treatment of obstructive sleep apnea and should be used under the supervision of a licensed healthcare provider. Individual therapy needs, pressure settings, and mask selection must be determined by a medical professional. This information is not a substitute for professional medical advice.

    General Inquiries

    There are no inquiries yet.

    More Products